RXDC HIGH FREQUENCY INTRA ORAL X-RAY UNIT

RXDC HIGH FREQUENCY INTRA ORAL X-RAY UNIT

Login to order

Simple and immediate: Wireless

The wireless remote controller lets the user control the device (by communicating with the X-ray tube) while enjoying full freedom of movement.
Access to exposure programmes is provided via two simple settings. The large display shows the sequential exposure monitor and the patient exposure dose; moreover, the controller has a wireless X-ray snapshot button. Wireless device control allows fast, easy installation: no fixed control panels are required, thus providing greater freedom when positioning the X-ray unit.
MAXIMUM QUALITY
With a tiny focal spot of 0.4 mm (at 30 cm), RXDC - HyperSphere technology produces sharp images under any condition. The tube head is now even more powerful as it operates at 70 kV, 8 mA. RXDC - HyperSphere technology gives your surgery the precision and quality of cuttingedge know-how.

MINIMUM DOSE

The constant potential high frequency (DC) generator reduces the most harmful low energy radiation that is characteristic of analogue (AC) generators: current is adjustable (from 8 mA to 4 mA), as are exposure times. Moreover, the long cone (30 cm) with incorporated rectangular collimator reduces the exposed surface area. This maximises image quality and safeguards patient and worker health.
MULTI-MODE
Maximum flexibility to meet your diagnostic needs. Automatic parameter modulation ensures exposure power and time are always selected according to the patient’s build and the specific region of investigation.
SEQUENCED EXPOSURE
The dynamic service cycle allows uninterrupted use of the RXDC, as in the case of systematic examinations, and real-time monitoring of tube head temperature on the large wireless controller display.
OMPLETE EQUIPMENT SET
RXDC - HyperSphere technology features a 30 cm cone with a circular and rectangular collimator. The rectangular collimator is ideal for reducing the X-ray dose administered to the patient as it limits the irradiated body area to the effective capture capacity of the sensor.

Technical Specifications

TECHNICAL DATA
Generator Constant potential, microprocessor-controlled
Working frequency 145-230 KHz (typically 175 KHz)
Focal spot 0,4 mm (IEC 336)
Anode current 4 / 8 mA
Voltage at X-ray tube 60 / 65 / 70 kV (*)
Exposure time 0.020 – 1.000 seconds, R’10 and R’20 scale
Source-skin distance 20 e 30 cm
Irradiated field 35 x 45 mm rectangular, Ø 55 mm and Ø 60 mm round
Additional collimators 31 x 41 mm and 22 x 35 mm, for size 2 and size 1 sensors
Total filtration 2.0 mm Al @ 70kV
Power supply 50/60 Hz, 115-120Vac ±10% o 230-240Vac ±10%
Duty Cycle continuous operation with self-adjustment up to 1s/80s total
Stability Automatic lock/release, with touch-sensitive activation (HyperSphere technology)
Arms Available in 3 lengths: 40 cm - 60 cm - 90 cm
Max. arm extension 230 cm, from wall
Certification CE 0051, FDA approved
(*) values depend on the country where the product is marketed.